Operator's handbook for the TransTech PQI380 pavement quality indicator, covering setup, reading modes, calibration, data management, and maintenance.
The TransTech PQI380 is a non-nuclear pavement quality indicator that uses impedance spectroscopy to calculate asphalt pavement density. It is intended primarily for newly-laid asphalt pavements with lift thickness from 0.75 inches to 6 inches.
This handbook describes the gauge's controls and components, setup steps, reading modes, calibration and offset procedures, data management and download, power-save behavior, maintenance and troubleshooting, standardization, and warranty.
| Measurement technology | Impedance Spectroscopy |
|---|---|
| Measurement units | pcf or kg/m³ |
| Portable operation | 12 hours |
| Data storage | Infinite records |
| Data download interface | USB flash drive |
| Data file format | Semicolon delimited text file |
| Power source | Non-nuclear, low-voltage direct current |
| Intended lift thickness | 0.75 to 6 inches |
| Operating temperature | -4 to 104 °F (-20 to 40 °C) |
| Operating relative humidity | 10% to 90% noncondensing |
| Sensor plate | 10 inches |
| Display | 480x640 VGA touch screen |
| GPS accuracy | 5+- meters |
| Battery charge time | Approximately 4 hours |
| Fully charged battery voltage | Over 8 volts |
| Low battery indication | Approximately 6.5 volts |
| Additional readings after low voltage | About 12 to 15 |
| Charger | 120/220V AC to 12V DC |
| Battery packs included | 3 |
| Warranty | 1 year from date of shipment |
It uses impedance spectroscopy to measure the electrical response of asphalt.
Newly-laid asphalt pavements with lift thickness from 0.75 inches to 6 inches.
No; it uses non-nuclear, low-voltage direct current.
Approximately 4 hours.