This user guide provides instructions for the safe unpacking, installation, operation, and remote control configuration of the TPL Vision Modular Ringlight.
This document serves as the user guide for the TPL Vision Modular Ringlight, covering safety precautions, unpacking procedures, and physical installation dimensions. It details the product's default operating modes, including manual control and continuous working (CW) mode, as well as the setup for remote control via PNP or NPN signals. This manual is written in French.
| Dome Length (80mm) | 80 mm |
|---|---|
| Ring Length (130mm) | 130 mm |
| Low Angle Length (80mm) | 80 mm |
| Max Strobe Frequency (Overdrive) | 310 Hz |
| Max Duty Cycle (Overdrive) | 10% |
| Max Trigger Signal Duration | 2ms |
Press both the colour and sector buttons at the same time again during 3-4 seconds to save the settings.
Do not exceed 310 Hz when strobing PNP/NPN in overdrive mode.
Connect the remote control cable and apply 0V to the active overdrive pin (Pin 1) to activate overdrive.