Leaflet for the TOHO-TEC FLX (Flexus) Series thin film stress measurement system: non-contact dual-laser stress and deflection measurement, model lineup and…
The TOHO-TEC FLX (Flexus) Series is a thin film stress measurement system that uses dual laser technology to measure sample deflection and film stress without contact or destruction. A laser is reflected on the surface of the sample; samples before and after film deposition are measured separately, and the difference in the curvature radius of the samples is used to calculate the film stress. Data output includes stress (MPa), deflection (um), BOW (um), radius (um), graphs and 3D mapping. The leaflet lists applications in research and development of substrate and film materials, quality control of film deposition and coating equipment, optimizing the film process in semiconductor and display manufacturing, and film quality management in various industries, and it states a top global market share in desktop stress metrology systems as well as "Made in Japan with high quality and service".
The lineup covers four models: FLX2320 S and FLX2320 R for 3 to 8 inch samples, and FLX3300 T and FLX3300 R for 8 to 12 inch samples. Stated values include a measurement range of 1 to 4000 MPa, measurement repeatability (1σ) of ±1.3 MPa, measurement lasers of 670 nm and 780 nm, measurement temperatures from room temperature to 500 °C, manual or automatic sample rotation, 100 V or 230 V power supply, CDA / N2 gas, and standard weights of 48 kg and 60 kg. Options listed are stress standard, locators, 3D software, offline software, transformer, low-temperature (−65 °C) and others. This manual is written in Japanese.
| Sample size | 3 to 8 inch (FLX2320 S / FLX2320 R); 8 to 12 inch (FLX3300 T / FLX3300 R) |
|---|---|
| Measurement range | 1 to 4000 MPa |
| Measurement lasers | 670 nm, 780 nm |
| Measurement temperature | Room temperature to 500 °C |
| Data output | Stress (MPa), deflection (um), BOW (um), radius (um), graph, 3D mapping |
| Power supply | 230 V or 100 V |
| Standard weight | 48 kg / 60 kg |
| Options | Stress standard, locators, 3D software, offline software, transformer, low-temperature (−65 °C), etc. |
A laser is reflected on the sample surface, samples before and after film deposition are measured separately, and the difference in curvature radius of the samples is used to calculate the film stress.
It is non-contact and non-destructive; the system uses dual laser technology to measure sample deflection and film stress.
FLX2320 S and FLX2320 R handle 3 to 8 inch samples, while FLX3300 T and FLX3300 R handle 8 to 12 inch samples.
The stated range is room temperature to 500 °C, and a low-temperature (−65 °C) option is listed.