This manual covers the installation, configuration, and Modbus-RTU communication protocols for the THT THT-03R temperature and humidity transmitter.


THT THT-03R Temperature and Humidity Transmitter User Manual - cover page
Brand
THT
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
937 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
56F1B61E466B08088D528B3503948430

About this manual

The THT THT-03R is a temperature and humidity transmitter designed with an RS-485 communication interface compatible with the standard Modbus-RTU protocol. It utilizes SHT30 sensing elements for high reliability and stability in high-humidity environments. The device features a built-in display and indicator light for intuitive status monitoring and uses DIP switches for address setting to simplify maintenance and replacement. This manual is written in Chinese.

What's inside

  • Overview
  • Features
  • Application Areas
  • Technical Data
  • DIP Switch and Address Code
  • Communication Protocol
  • Host Reading Sensor Information
  • Host Setting Sensor Information
  • Error Response
  • CRC Checksum Calculation

Specifications

Supply VoltageDC 5~36V
Temperature Measurement Range-40~120℃
Humidity Measurement Range0~100%RH
Temperature Accuracy±0.2℃
Humidity Accuracy±2%RH
Communication ProtocolModbus-RTU
Maximum Transmission Distance1200m

Frequently asked questions

How is the device address set?

The address is set using the DIP switch on the device.

What is the update rate of the sensor data?

The temperature and humidity data updates every 30 seconds.

Which communication protocol does the device support?

The device supports the standard Modbus-RTU protocol.