Owners manual and parts list for Thieman M16 and M20 liftgate models, covering operation, maintenance, and inspection.
This document serves as the owners manual and parts list for the Thieman M16 and M20 liftgate models. It provides essential safety warnings, operating instructions for unfolding and folding the platform, and guidelines for proper loading to prevent damage or injury.
The manual also details a comprehensive maintenance guide, including monthly and semi-annual inspection procedures, lubrication schedules, and hydraulic fluid specifications. Additionally, it includes a parts ordering procedure and a troubleshooting guide to assist with repairs and maintenance.
| M16 Rated Capacity | 1600LBS |
|---|---|
| M20 Rated Capacity | 2000LBS |
| Max Amp Draw (M16/20 ET) | 205 |
| Relief Pressure (M16/20 ET) | 2500 psi |
| Max Amp Draw (M16/20 EST) | 255 |
| Relief Pressure (M16/20 EST) | 2650 psi |
The maximum rated capacity of the M16 liftgate is 1600LBS.
The maximum rated capacity of the M20 liftgate is 2000LBS.
The liftgate can be cycled no more than 3 cycles/10 minutes constantly with a maximum load.