Termoakim GALAXI SMART SERIES Electric Combi Boiler User Manual

This user manual provides installation, electrical connection, operation, maintenance, and troubleshooting instructions for the Termoakım GALAXI SMART…


Termoakim GALAXI SMART SERIES Electric Combi Boiler User Manual - cover page
Brand
Termoakım
Category
Other products
Document type
User Manual
Language
English
Pages
19
File format
PDF
File size
830 KB
Published
29 October, 2026
Updated
29 October, 2026
MD5 checksum
1EF931F58E425E15ACF7EDF73D4EF6EF

About this manual

The Termoakım GALAXI SMART SERIES is an electric combi boiler designed to provide heating and hot water. The device features an easy-to-open cover for intervention and includes various safety mechanisms such as a reset safety thermostat, low pressure sensor, and automatic air evacuation system.

Installation requires adherence to specific spacing guidelines (minimum 50 cm clearance) and proper electrical connections based on the unit's power rating (6-36 kW). The manual details monophase and triphase connection methods, external hot water tank integration using a three-way valve and heat sensor, and periodic maintenance procedures including resetting error codes.

What's inside

  • Parts Of Electric Boiler
  • Device Installation
  • Opening The Device Cover
  • Installation Connection
  • External Hot Water Tank Connection
  • Electrical Connection
  • Initial Operation
  • Using The Control Panel
  • Device Error Information
  • Periodic Maintenance

Specifications

Minimum Operating Pressure0.8 bar
Maximum Operating Pressure1.5 bar

Frequently asked questions

What is the minimum water pressure required for operation?

The device requires a minimum pressure of 0.8 bar to operate correctly.

How do I reset the Safety Thermostat Error?

Insert your hand through the opening at the bottom, remove the cover, wait for cooling, press the reset button until it snaps into place with a click.

Can this boiler be used with an external hot water tank?

Yes, it can operate in external hot water tank mode on demand using a fully transitive three-way valve and a heat sensor.