Teledyne e2v A1A-CX1193C Deuterium-Filled Four-Gap Ceramic Thyratron Datasheet

Teledyne e2v A1A-CX1193C deuterium-filled four-gap ceramic thyratron datasheet with ratings, characteristics, cooling, connections, and outline dimensions.


Teledyne e2v A1A-CX1193C Deuterium-Filled Four-Gap Ceramic Thyratron Datasheet - cover page
Brand
Teledyne e2V
Category
electronic components
Document type
Datasheet
Language
English
Pages
6
File format
PDF
File size
333 KB
Published
23 November, 2026
Updated
23 November, 2026
MD5 checksum
E1B6845669DA36BE940867CC04657B6E

About this manual

This document is an abridged datasheet for the Teledyne e2v A1A-CX1193C, a deuterium-filled four-gap thyratron with a ceramic envelope. It lists electrical, mechanical, environmental, and characteristic data for modulator and crowbar service.

The datasheet also covers cooling requirements, maximum and minimum ratings, notes, health and safety hazards, schematic diagrams, recommended connections, and outline dimensions.

What's inside

  • Abridged Data
  • General Data
  • Cooling
  • Maximum and Minimum Ratings
  • Characteristics
  • Notes
  • Health and Safety Hazards
  • Schematic Diagram
  • Recommended Connections
  • Outline

Specifications

Peak anode voltage (modulator service)130 kV max
Peak forward anode current (modulator service)10 kA max
Average anode current4.0 A max
Peak anode voltage (crowbar service)100 kV max
Peak forward anode current (crowbar service)40 kA max
Conducted charge (crowbar service)18 C max
Cathode heater voltage6.3 + 0.3 V
Cathode heater current40 A
Reservoir heater voltage5.0 V
Reservoir heater current10 A
Tube heating time15 min min
Seated height479 mm max
Clearance below mounting flange60 mm min
Overall diameter152.4 mm max
Net weight10.8 kg max

Frequently asked questions

How must the tube be cooled?

The tube must be cooled by total liquid immersion, for example in force circulated transformer oil.

What is the minimum tube heating time?

The minimum tube heating time is 15 minutes.

What mounting positions are allowed?

The tube may be mounted in any position.

What X-ray shielding is recommended?

Shielding the thyratron with at least 1.6 mm thick steel panels is recommended.