TAKEDO 3VF NXP Inverter Drive User Manual

User manual for the TAKEDO 3VF NXP inverter drive, covering setup, safety, wiring, motor identification, parameters and maintenance in lift applications.


TAKEDO 3VF NXP Inverter Drive User Manual - cover page
Brand
TAKEDO
Category
inverter
Document type
User Manual
Language
English
Pages
50
File format
PDF
File size
2.8 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
99D9D9DF66ACC9D60865F6B863923D7A

About this manual

The TAKEDO 3VF NXP is an inverter drive with a built-in EMC filter and smoothing choke. It can operate in open loop and closed loop modes; closed loop operation requires an optional circuit board and an encoder. The manual describes starting up and operating the drive and refers to an annex for lift control panel wiring.

The document includes quick guides for open loop asynchronous motors, closed loop asynchronous motors, and permanent magnet synchronous motors. It also covers safety warnings, power connection, EMC, application diagrams, keypad and menu use, adjustments, encoder setup, active faults and alarms, fault history, maintenance, parameters, and an EC conformity declaration.

What's inside

  • Safety Warnings and Precautions
  • Power Connection
  • Electromagnetic Compatibility (EMC)
  • Application Diagrams
  • Keypad and Menu
  • Active Faults and Alarms
  • Encoder for Asynchronous Motors
  • Encoder for Synchronous Motors
  • Maintenance
  • Parameters

Specifications

Operating modesOpen loop and closed loop
Built-in filterEMC filter and smoothing choke
Leakage current to groundGreater than 30 mA
Differential circuit breakerId not less than 300 mA, type B or type A
Ground cable sectionNot less than 10 mm²

Frequently asked questions

What motor types can the TAKEDO 3VF NXP drive?

It is intended for asynchronous motors or permanent magnet synchronous motors.

Can the front cover be removed during operation?

No; never remove the cover during operation, and power up the inverter only with the front cover fitted.

How should the external braking resistor be connected?

The braking resistor must be connected between B+ and R-.

What should be done if the inverter has not been powered for one year or more?

Regenerate the bus capacitors by powering the drive with operation prevented for 1 hour at less than 50% rated voltage, then for 1 hour at rated input voltage.