Syrelec Crouzet NTR 804 C 7X41 / 7X42 Up/Down Counter Installation Manual

Installation manual for the Syrelec Crouzet 7X41 and 7X42 up/down counters, covering display, inputs, outputs, supply, installation, wiring and programming.


Syrelec Crouzet NTR 804 C 7X41 / 7X42 Up/Down Counter Installation Manual - cover page
Brand
Syrelec Crouzet
Category
Counter
Document type
Other
Language
English
Pages
11
File format
PDF
File size
650 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
55FFDAB51547E62CAEF64FFB5303F928

About this manual

The 7X41 and 7X42 are 72 x 72 format up/down counters with 6 decades, up to 2 presets and a back-lit LCD display. They provide two inputs (IN1 and IN2), one inhibit input, eight input modes, and a counting frequency of 5 KHz, or 2.5 KHz in Phase 4; debounce mode is limited to 30 Hz.

The manual covers installation, supply voltage ranges, input and output wiring, reset, scale factor and decimal point settings, and programming. It explains programming mode, RUN mode and backup, and includes wiring diagrams and input-mode diagrams.

What's inside

  • Main characteristics
  • Display
  • Inputs
  • Reset
  • Solid-state output
  • Relay output
  • Supply
  • Installation
  • Programming
  • Wiring diagrams

Specifications

Format72 x 72
Decades6
Presets2 maximum
Display digits6 digits, 10 mm high
Display typeback-lit LCD (71XX); red display (73XX)
Inputs2 inputs (IN1, IN2) plus 1 inhibit input
Counting frequency5 KHz; 2.5 KHz in Phase 4
Supply voltage10 to 30 VDC, 20 to 55 VAC or 80 to 260 VAC
Power consumption4 W, 5 VA or 10 VA
Solid-state outputNPN, 100 mA maximum
Relay output (7X41)1 changeover relay (1RT)
Relay output (7X42)2 changeover relays (2RT)
Operating temperature0 °C to +55 °C
Weight250 g
Front panel protectionIP54

Frequently asked questions

What supply voltage ranges are available?

Models accept 10 to 30 VDC, 20 to 55 VAC or 80 to 260 VAC.

How many presets does the counter support?

It supports up to 2 presets maximum.

What is the high-speed counting frequency?

It is 5 KHz, or 2.5 KHz in Phase 4.

How can the counter be reset electrically?

It can be reset by contact, voltage or a solid-state device (NPN or PNP).

Download PDF (650 KB)