A lab guide for Synopsys Design Compiler 1 covering timing and area constraints, setup, synthesis flow, and hands‑on lab tasks.
This workshop lab guide provides step‑by‑step instructions for using Synopsys Design Compiler 1. It walks users through updating setup files, invoking Design Vision, reading RTL, applying constraints, and exploring schematic and symbol views.
The document also includes design specifications such as clock frequency, delay limits, and area goals, as well as a series of synthesis technique labs that discuss multi‑cycle timing, adaptive retiming, and optimization strategies.
| Clock frequency | 333.33 MHz |
|---|---|
| Maximum external clock generator delay | 700 ps |
| Maximum design area goal | 540 area units |
The Link library is the library used for linking the design, shown in the Setup window of Design Vision.
The Target library is the library that provides the technology cells for synthesis, displayed in the Setup window.
The user directories added to the Search path are listed in the Set Search Path window, typically the tool installation library directories.