SVF EZ-Tork Pneumatic Actuator Installation, Operation & Maintenance Manual

Installation, operation and maintenance instructions for the SVF EZ-Tork rack and pinion pneumatic actuator, including safety, assembly and replacement parts.


SVF EZ-Tork Pneumatic Actuator Installation, Operation & Maintenance Manual - cover page
Brand
SVF
Category
Other
Document type
Service Manual
Language
English
Pages
8
File format
PDF
File size
484 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
137C1290BF02C10D9B1E356FF1CCAB08

About this manual

The SVF EZ-Tork is a rack and pinion pneumatic actuator supplied as a double-acting or spring-return unit. The manual describes its 90° rotation, stroke adjustment at 0° and 90°±5°, operating media, supply pressure and temperature ranges, and the principle of operation for both versions.

It then covers assembly to a valve, disassembly, inspection and maintenance, recommended replacement parts, and reassembly. Safety warnings address isolation of pressure and electrical connections, stored spring energy, and checking valve and actuator rotation before installation.

What's inside

  • Important Safety Warnings
  • General
  • Description of EZ-Tork Actuators
  • Lubrication
  • Principle of Operation
  • Assembly to Valve
  • Disassembly of the Actuator
  • Inspection and Maintenance
  • Recommended Replacement Parts
  • Assembly of the Actuator

Specifications

Actuator typeDouble-acting or spring-return rack and pinion
Rotation90° with stroke adjustment at 0° and 90°±5°
Minimum supply pressure40 psig (2.5 bar)
Maximum supply pressure120 psig (8 bar)
Standard operating temperature-5°F to 176°F (-15°C to +80°C) with Buna O-ring
High-temperature operating range-5°F to +300°F (-15°C to +150°C) with Viton O-ring
Low-temperature operating range-76°F to +176°F (-60°C to +80°C) with Silastic O-ring
Body materialHard anodized aluminum alloy
Drive shaft materialAlloy steel, nickel plated
Maximum particle size30 µm

Frequently asked questions

Does the EZ-Tork actuator need additional lubrication?

No. The manual states that the actuator is supplied ready-lubricated and no further lubrication is required.

What is the maximum supply pressure for the actuator?

The maximum supply pressure is 120 psig (8 bar).

What should be checked before assembling the actuator to a valve?

Check that the valve and actuator are in the same position, open or closed.

What caution applies to spring-return actuators during disassembly?

Make sure the actuator is in the failed position before disassembling it.