This manual covers the operation, installation, settings, and maintenance of the Supmea U-SUP-LUGB-YHCN6 vortex flowmeter for measuring liquid, gas, and steam.
The document is a user's manual for the Supmea U-SUP-LUGB-YHCN6 vortex flowmeter. It explains that the device uses the Karman vortex street principle to measure the flow of liquids, gases, and steam, including those with small particles or impurities. The manual details the working principles, technical parameters such as accuracy grades and pressure ratings, and various output forms like frequency pulses and 4-20mA current. This manual is written in Chinese.
| Measurement Media | Liquid, Gas, Steam (Saturated/Supersaturated) |
|---|---|
| Nominal Diameter Range | DN15-DN300 |
| Accuracy (Gas Uncompensated) | 1.5 Grade for DN15-DN25, 1.0 Grade for DN32-DN200 |
| Accuracy (Liquid Uncompensated) | 1.0 Grade |
| Operating Temperature Range | -40℃ to +150℃, -40℃ to +260℃, or -40℃ to +300℃ |
| Working Power Supply | 24VDC±5% or Lithium Battery 3.6VDC (optional) |
| Communication Protocols | RS485, HART (optional) |
Yes, it can also measure turbid liquids containing small particles or impurities.
No, this product is prohibited from use in explosion-proof occasions.
Outputs include working condition frequency, equivalent pulses, two-wire 4-20mA current, and two-wire current percentage.