Installation planning guide for the Sun SPARC Enterprise T2000 server, covering physical dimensions, environmental limits, power, acoustics and compliance.
This guide lists the installation environment specifications and requirements for the Sun SPARC Enterprise T2000 server. It covers physical dimensions, maintenance clearance, environmental limits, power input, acoustic emissions, regulatory compliance and recommended operating conditions.
The server has two auto-ranging power supplies and is a 2U rack system. Recommended ambient temperature is 21 to 23 C (69.8 to 73.4 F), with optimal humidity and airflow considerations also described. This manual is written in Spanish.
| Width | 17.3 in (440 mm) |
|---|---|
| Depth | 24.3 in (617 mm) |
| Height | 3.5 in (89 mm), 2 rack units |
| Approximate weight | 40 lb (18 kg), without PCI cards or rack mounting parts |
| Front clearance | 91 cm (36 in) |
| Rear clearance | 91 cm (36 in) |
| Operating temperature (sea level to 900 m) | 41 to 95 F (5 to 35 C) |
| Operating temperature above 900 m | Maximum temperature decreases 1 C per 300 m (1.6 F per 1000 ft) |
| Non-operating temperature | -40 to 60 C |
| Operating humidity | 20 to 80% relative humidity |
| Operating altitude | 0 to 3,000 m (0 to 10,000 ft) |
| Non-operating altitude | 0 to 12,000 m (0 to 40,000 ft) |
| Operating vibration | 0.2 G sinusoidal sweep, 5-500-5 Hz |
| Operating shock | 5 G peak, 11 ms half-sine pulse |
| Input voltage | 100 to 240 VAC, 50-60 Hz |
| Maximum input current | 4.5 A at 100-120 VAC; 2.25 A at 200-240 VAC |
| Maximum input power | 450 W |
| Maximum heat dissipation | 1,365 BTU/h (1,440 KJ/h) |
| Sound power level | 7.7 B, operating and idle |
| Sound pressure level | 62 dB, operating and idle |
| Recommended ambient temperature | 21 to 23 C (69.8 to 73.4 F) |
Width is 17.3 in (440 mm) and depth is 24.3 in (617 mm).
100 to 240 VAC at 50-60 Hz, with a maximum input power of 450 W.
21 to 23 C (69.8 to 73.4 F).
7.7 B in operating and idle modes.