Technical guide for Sun Hydraulics proportional amplifiers covering types, wiring, handheld programming, parameters, adjustment, and troubleshooting.
This document serves as a technical guide for Sun Hydraulics proportional amplifiers and accessories. It provides an overview of the amplifier types, including embedded and plug-in models, and details their specific applications and connection interfaces like DIN and Deutsch connectors.
The guide covers practical aspects such as wiring diagrams, operation of the handheld programmer (HHP), and configuration using software. It also includes sections on adjustable parameters, amplifier adjustment procedures, background theory regarding PWM and resolution, and a troubleshooting flowchart.
| Input Voltage Range | 9-28 VDC |
|---|---|
| Command Signal (Voltage) | 0-10 V DC |
| Command Signal (Current) | 0-20 mA |
| Recommended Fuse Rating | 2 Amps |
| Max Hold Current (24V Coil) | 590 mA |
| Max Hold Current (12V Coil) | 1150 mA |
Sun provides two main amplifier types: embedded amplifiers and plug-in amplifiers.
The recommended maximum fuse rating is 2 Amps.
The input voltage range is 9-28 VDC.
Adjustment is done using an infrared (IR) adapter and handheld programmer (HHP) or PC software.