Suburban Dynatrail Furnaces Service Manual NT-12S‑NT-42T

Service manual for Suburban Dynatrail RV furnaces covering safety, installation, operation, maintenance, and warranty for models NT‑12S through NT‑42T.


Suburban Dynatrail Furnaces Service Manual NT-12S‑NT-42T - cover page
Brand
Suburban
Document type
Service Manual
Language
English
Pages
22
File format
PDF
File size
328 KB
Published
28 September, 2026
Updated
28 September, 2026
MD5 checksum
170568C645D0F066A151FDD57CF2680F

About this manual

The Suburban Dynatrail Service Manual provides detailed safety guidelines, model specifications, and general service information for a range of RV forced‑draft furnaces. It includes installation instructions for venting, return air, and ducting, as well as gas pressure requirements and a step‑by‑step sequence of normal operation.

Further sections cover operation details, preventative maintenance, cautions, furnace removal procedures, service hints, diagnostic procedures, warranty terms, and a flat‑rate service schedule. The manual is intended for service technicians and qualified RV owners who need to troubleshoot, repair, or maintain these propane‑fired furnaces.

What's inside

  • Safety
  • Furnace Model Information
  • General Service Information
  • Installation – Venting, Return Air, Ducting
  • Gas Pressure Requirements
  • Sequence of Normal Operation
  • Operation Information
  • Maintenance
  • Cautions
  • Furnace Removal

Specifications

NT-12S BTU rating12,000 BTU/hr
NT-12S Current2.8 amps
NT-24SP BTU rating24,000 BTU/hr
NT-24SP Current3.5 amps
NT-42T BTU rating42,000 BTU/hr
NT-42T Current9.0 amps

Frequently asked questions

What gas pressure should be used with Suburban Dynatrail furnaces?

The operating pressure is between 10.5" and 13.0" of water column.

What voltage do the furnaces operate on?

Suburban furnaces operate on 12‑volt DC supplied by a 12‑volt battery or a converter system.

How often should the venting system be inspected?

The venting system should be inspected at least once a year, preferably before the heating season begins.

What should be done if the furnace goes into lockout?

When lockout occurs, the gas valve closes and will remain closed until the thermostat circuit is broken; the furnace must be reset by turning the thermostat off and then back on.