A product guide for Stego's Slab-On-Ground vapour mitigation system, detailing the Stego Wrap vapour barrier and related tapes for preventing moisture and…
This document serves as a product guide for the Stego Vapour Mitigation System, specifically designed for slab-on-ground applications. It highlights the benefits of using Stego's engineered films, such as the Stego Wrap Vapour Barrier, to protect building envelopes from moisture intrusion, soil gases like radon, and sulphates. The guide emphasizes that these products offer superior performance compared to traditional black polyethylene sheeting.
| Permeance | 0.0086 gr/(ft²*hr*in-Hg) |
|---|---|
| Puncture Resistance | 2,266 grams |
| Tensile Strength | 12.4 kN/m |
The main standard is ASTM E1745 Standard Specification for Plastic Water Vapour Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs.
It allows significant water vapour passage, often gets damaged during placement, and is frequently made from recycled materials with reduced anti-oxidants.