About this manual

This manual describes the SP712-2 loop‑powered 4‑20 mA transmitter, a 2‑wire device that converts a frequency input to a proportional current output. It includes key features such as selectable full‑scale frequency range, adjustable sensitivity, and a compact 1.7 lb enclosure suitable for direct mounting on flowmeters.

The document contains detailed specifications, wiring diagrams, typical loop configurations, and a step‑by‑step bench‑test calibration procedure. Users can follow the calibration steps to set zero, span, and sensitivity, and verify linearity across the selectable frequency range.

What's inside

  • Installation & Operation
  • Specifications
  • Bench Test Calibration Procedure
  • Typical Loop Configurations
  • Terminal Location

Specifications

Operating Temperature-40 to 85 °C
Storage Temperature-65 to 125 °C
Input VoltageMin 7 V + (20 mA×RL), Max 28 V + (4 mA×RL)
Signal Input Frequency0‑10 kHz
Signal Input Amplitude50 mV – 35 V sine or square wave
Impedance50 kΩ
Analog Output Current4 mA @ 0 Hz, 20 mA @ full‑scale frequency
Full‑Scale Frequency Range100 Hz‑10 kHz (selectable)
Response Time95 % of change in 1 s
Linearity±0.3 %
Weight1.7 lb

Frequently asked questions

How do you calibrate the SP712-2 transmitter?

Use the bench‑test calibration procedure: connect power, DMM, and frequency generator as shown, set zero to 4 mA, adjust span to 20 mA, and verify linearity at selected frequencies.

What is the operating temperature range of the SP712-2?

The transmitter operates from –40 °C to 85 °C and can be stored from –65 °C to 125 °C.

What input voltage does the SP712-2 require?

It needs a minimum of 7 V plus the loop voltage (20 mA×RL) and a maximum of 28 V plus the loop voltage (4 mA×RL).