Installation and operation instructions for Space Ray PBF infrared radiant poultry tube heaters, covering safety, wiring, venting and maintenance.
This manual provides detailed safety guidelines, installation requirements, and operating procedures for Space Ray infrared radiant poultry tube heaters. It covers both single‑stage (N5/L5) and two‑stage (N7/L7) gas valve options and includes instructions for gas, electrical, and ventilation connections.
The document also includes specifications, minimum clearances to combustibles, typical assembly layouts, troubleshooting steps, and a parts replacement guide to help installers and service technicians maintain reliable heater performance.
| High Input (2‑stage) BTU/hr (PBF 60) | 60,000 |
|---|---|
| Low Input BTU/hr (PBF 60) | 40,000 |
| Orifice Size – Natural Gas (PBF 60) | #27 (0.144) |
| Control Option – Single Stage Natural Gas | N5 |
| Control Option – Two Stage Propane Gas | L7 |
The heater can be installed for use with either Natural Gas or Propane (LP) Gas.
For the PBF 60 model the required clearances are 36 in. horizontally, 12 in. on the sides, 69 in. to the ceiling, and 32 in. below the ends.
The manufacturer provides a 12‑month warranty from the date of installation or 18 months from shipment, whichever expires first.