SMA Sunny Boy 1300TL / 1600TL / 2100TL Inverter Operating Manual

Operating manual for the SMA Sunny Boy 1300TL, 1600TL and 2100TL transformerless PV inverters, covering mounting, electrical connection, commissioning and…


SMA Sunny Boy 1300TL / 1600TL / 2100TL Inverter Operating Manual - cover page
Brand
SMA
Category
inverter
Document type
User Manual
Language
English
Pages
58
File format
PDF
File size
2.2 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
20E153809898CFB422A38B0604BA2248

About this manual

This operating manual from SMA Solar Technology AG covers the Sunny Boy 1300TL (SB 1300TL-10), Sunny Boy 1600TL (SB 1600TL-10) and Sunny Boy 2100TL (SB 2100TL) device types from firmware version 4.50. The Sunny Boy is a transformerless PV inverter that converts the direct current of the PV array to grid-compliant alternating current and feeds it into the utility grid, and is suitable for indoor and outdoor use.

The manual is intended for qualified persons and end users. It describes the scope of delivery, product description, mounting, AC and DC electrical connection, commissioning (including a self-test in accordance with CEI 0-21 for PV systems ≤6 kW), configuration, operation and display messages, disconnecting the inverter from voltage sources, technical data, accessories and the EC Declaration of Conformity.

What's inside

  • Information on this Document
  • Safety
  • Scope of Delivery
  • Product Description
  • Mounting
  • Electrical Connection
  • Commissioning
  • Configuration
  • Operation
  • Technical Data

Specifications

Device types coveredSB 1300TL-10, SB 1600TL-10, SB 2100TL (from firmware version 4.50)
Inverter typeTransformerless PV inverter
Installation locationIndoor and outdoor use
Required PV arrayProtection class II in accordance with IEC 61730, application class A
Max. PV coupling capacity to ground1.4 μF
Degree of protectionIP65 (with ESS plugged in and inverter closed)
Heat sink temperatureCan reach over 70°C during operation

Frequently asked questions

Which Sunny Boy models does this manual cover?

It is valid for the Sunny Boy 1300TL (SB 1300TL-10), Sunny Boy 1600TL (SB 1600TL-10) and Sunny Boy 2100TL (SB 2100TL) from firmware version 4.50.

Can the Sunny Boy be installed outdoors?

Yes, the product is suitable for indoor and outdoor use.

Who is allowed to mount, install and commission the inverter?

Only qualified persons with the appropriate skills may mount, install and commission the inverter; tasks without particular requirements can also be performed by end users.

How should the inverter be cleaned?

Clean the enclosure, enclosure lid, type label, display and LEDs with a damp cloth only, as cleaning agents can damage the display or the type label.

Download PDF (2.2 MB)

More SMA Manuals


View all SMA manuals →