Slant/Fin Galaxy/Sentinel/Sentry Series Boiler Automatic Vent Damper Installation Guide

Installation instructions and troubleshooting guide for the Slant/Fin automatic vent damper used on Galaxy, Sentinel and Sentry series boilers.


Slant/Fin Galaxy/Sentinel/Sentry Series Boiler Automatic Vent Damper Installation Guide - cover page
Brand
Slant/Fin
Category
Heater
Document type
Installation Guide
Language
English
Pages
4
File format
PDF
File size
302 KB
Published
23 November, 2026
Updated
23 November, 2026
MD5 checksum
0396B18AD244B1C4C5C48446DFDA9EF4

About this manual

This manual provides installation instructions and a troubleshooting guide for the automatic, motorized vent damper designed for Slant/Fin Galaxy, Sentinel and Sentry series gas boilers. It must be left with the owner and hung on or adjacent to the boiler for reference.

The damper increases heating system efficiency by closing the chimney vent when the burner is off and opening it when combustion is required. Installation must conform to the National Fuel Gas Code ANSI Z223.1 and, where required, ASME CSD-1, and the device must be installed by a qualified installer.

What's inside

  • Introduction
  • Description
  • Electrical
  • Features
  • Installation Instructions
  • General Information
  • Vent Size Approx Ship Wt.

Specifications

Vent sizes4", 5", 6", 7", 8", 9", 10"
Wiring voltage24VAC
Life cycle test100,000 trouble-free operations
Clearance from combustible materials6 inches (152 mm)
CertificationCSA retrofit certification ANSI Z21.66

Frequently asked questions

Which boilers must use a vent damper?

Boilers with input under 300,000 Btu/hr must use a vent damper.

Where should the vent damper be installed?

It must be installed on the outlet end of the draft hood as close to the draft hood as practicable.

What happens if the damper does not rotate to open?

The burner circuit will not be activated.

What minimum wiring is required?

24VAC, 18 gauge, 90°C wiring is required.

Download PDF (302 KB)