Simco TensION 815-041 Volt Stick Operating Instructions

Operating instructions for the Simco TensION 815-041 Volt Stick, a non-contact voltage detector for checking ionising emitters and charging points on…


Simco TensION 815-041 Volt Stick Operating Instructions - cover page
Brand
Simco
Category
Other Electronics
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
279 KB
Published
28 October, 2026
Updated
28 October, 2026
MD5 checksum
1FF327EF359C920EAEF2FF29AFD5DE15

About this manual

The Simco TensION 815-041 Volt Stick is a handheld device designed to detect high voltage on ionising emitters or charging points without requiring physical contact. Powered by two AAA batteries, it features a red indicator in the plastic tip that illuminates when high voltage is present. The device is intended for use with AC/DC Simco discharging and charging equipment, including anti-static and charging bars.

To ensure safe and correct operation, users must maintain specific minimum distances between the device and the emitters based on the operating voltage. The manual provides a table detailing these distances, ranging from 5 mm for 3.3 kV up to 80 mm for 30 kV. It is noted that the TensION indicates the presence of high voltage but does not perform a performance test; for that, an FMX-003 electrostatic fieldmeter is recommended.

What's inside

  • Operating instructions
  • Test method
  • Minimum distance
  • Technical specifications
  • Safety notes

Specifications

Power2 size AAA replacable batteries 1,5 volts
Measurement categoryCAT I
Weight40 grams
DimensionsLength 148 mm, diameter maximum 17 mm
MaterialRadilon-S HS(a), BE 170MO
Operating temperature-10ºC - +50ºC

Frequently asked questions

Does the TensION require contact to detect voltage?

No, the device does not require contact to detect voltage.

What indicates that high voltage is present?

A red indicator in the plastic tip will illuminate.

Can the TensION be used for performance testing?

No, it only indicates if high voltage is present; an FMX-003 electrostatic fieldmeter is used for performance testing.