AN119 Calculating Settling Time for Switched Capacitor ADCs Application Note

This application note describes methods for calculating settling time requirements for Silicon Laboratories C8051Fxxx SAR ADCs and external input circuitry.


AN119 Calculating Settling Time for Switched Capacitor ADCs Application Note - cover page
Brand
Silicon Laboratories
Category
microcontrollers
Document type
Application Note
Language
English
Pages
8
File format
PDF
File size
227 KB
Published
20 October, 2026
Updated
20 October, 2026
MD5 checksum
D73C739FAA7B2477D3400DF643E2C9A2

About this manual

This document explains how to calculate the required settling time for accurate Analog-to-Digital Converter (ADC) measurements using devices in the C8051Fxxx family. It details the equivalent circuits for both single-ended and differential measurements, noting that a minimum of 1.5 µs is required regardless of external circuitry speed.

The guide provides equations to determine settling time based on input impedance, capacitance, and desired accuracy (LSB). It also discusses specific design techniques such as low-power tracking mode, which ensures the internal 1.5 µs minimum requirement is met automatically, and methods for managing external anti-aliasing filters.

What's inside

  • Relevant Devices
  • Equivalent Circuit
  • Differential Ended Measurement
  • Minimum Settling Time Specification
  • Settling Time of the ADC Input Circuit
  • External Circuit Settling Time
  • Low-Power Tracking Mode
  • Manually Controlling Settling Time
  • Multiple ADC Inputs

Specifications

Minimum settling time specification1.5 µs
Equivalent input impedance (conservative estimate)5 kΩ
Equivalent input capacitance (conservative estimate)10 pF
Data conversion time (software trigger, ADCTM=0)16 SAR clock cycles

Frequently asked questions

What is the minimum settling time required by Silicon Laboratories ADCs?

The specification requires a minimum tracking time of 1.5 µs.

How does low-power tracking mode ensure settling time requirements are met?

It tracks for 3 SAR clock cycles before conversion; with a max frequency of 2 MHz, this takes at least 1.5 µs.

What external circuitry parameters affect settling time?

The input filter's capacitance and output impedance affect the settling time.

Does differential measurement change the settling time compared to single-ended?

No, the product of resistance and capacitance (time constant) remains the same.

Download PDF (227 KB)