This application note describes methods for calculating settling time requirements for Silicon Laboratories C8051Fxxx SAR ADCs and external input circuitry.
This document explains how to calculate the required settling time for accurate Analog-to-Digital Converter (ADC) measurements using devices in the C8051Fxxx family. It details the equivalent circuits for both single-ended and differential measurements, noting that a minimum of 1.5 µs is required regardless of external circuitry speed.
The guide provides equations to determine settling time based on input impedance, capacitance, and desired accuracy (LSB). It also discusses specific design techniques such as low-power tracking mode, which ensures the internal 1.5 µs minimum requirement is met automatically, and methods for managing external anti-aliasing filters.
| Minimum settling time specification | 1.5 µs |
|---|---|
| Equivalent input impedance (conservative estimate) | 5 kΩ |
| Equivalent input capacitance (conservative estimate) | 10 pF |
| Data conversion time (software trigger, ADCTM=0) | 16 SAR clock cycles |
The specification requires a minimum tracking time of 1.5 µs.
It tracks for 3 SAR clock cycles before conversion; with a max frequency of 2 MHz, this takes at least 1.5 µs.
The input filter's capacitance and output impedance affect the settling time.
No, the product of resistance and capacitance (time constant) remains the same.