SIGMACOVER 630 Epoxy Paint Data Sheet

Technical data sheet for SIGMACOVER 630 epoxy paint, detailing performance, application, mixing ratios, safety and specifications.


SIGMACOVER 630 Epoxy Paint Data Sheet - cover page
Brand
Sigma
Category
Other
Document type
Datasheet
Language
Chinese
Pages
4
File format
PDF
File size
127 KB
Published
01 October, 2026
Updated
01 October, 2026
MD5 checksum
4A095E613327BA3209C7C46A46123130

About this manual

SIGMACOVER 630 is a two‑component, thick‑film epoxy paint designed for low‑surface‑preparation steel, concrete and marine structures. It offers excellent corrosion resistance, impact and abrasion resistance, and can be applied over a variety of existing coatings.

The product is mixed at a base‑to‑curing‑agent ratio of 83:17, with recommended open times and curing schedules depending on temperature. Application methods include spray, brush and roller, each with specific recommended film thicknesses and dilution limits. Safety guidelines require ventilation, avoidance of inhalation and skin contact, and adherence to the listed VOC limits. This manual is written in Chinese.

What's inside

  • Introduction
  • Technical Data
  • Mixing Ratio
  • Safety Precautions
  • Film Thickness and Coating Rate
  • Recoat Interval Table
  • Curing Time Table
  • Open Time After Mixing
  • Global Applicability

Specifications

Density1.4 g/cm³
Solid Content83 % ± 2 %
Maximum VOC166 g/kg
Recommended Dry Film Thickness (brush/roller)60–100 µm
Theoretical Coating Rate (125 µm)6.6 m²/L
Mixing Ratio (Base : Curing Agent)83 : 17
Open Time at 20 °C2 hours
Flash Point (Base)31 °C

Frequently asked questions

What is the recommended mixing ratio for SIGMACOVER 630?

The base component and curing agent should be mixed in a volume ratio of 83 : 17.

What dry film thickness should be applied when brushing or rolling?

A dry film thickness of 60 µm to 100 µm is recommended for brush or roller application.

What safety measures are required when handling this epoxy paint?

Use adequate ventilation, avoid inhaling paint mist, and prevent skin and eye contact with the uncured paint.