SICK-STEGMANN TTK70 Absolute Linear Measuring System Datasheet

Technical datasheet for the SICK-STEGMANN TTK70 absolute, non-contact linear measuring system for linear motors, featuring HIPERFACE interface and RS-485…


SICK-STEGMANN TTK70 Absolute Linear Measuring System Datasheet - cover page
Brand
SICK STEGMANN
Category
Industrial Robot
Document type
Datasheet
Language
English
Pages
12
File format
PDF
File size
1.6 MB
Published
05 November, 2026
Updated
05 November, 2026
MD5 checksum
1882D7CB67BCD97A2EEA71613039FB63

About this manual

The TTK70 is an absolute, non-contact linear measuring system designed for linear motors. It consists of a reading head and a magnetic tape with a twin-track code containing both incremental and absolute tracks. The system calculates absolute position values without requiring a reference run and transmits data via the HIPERFACE interface while providing incremental sine/cosine signals.

What's inside

  • General features
  • Dimensions and tolerances
  • Technical data
  • Ordering information
  • Electrical interface
  • Signal specification
  • Type-specific settings
  • Overview of status messages
  • Sensor adjustment

Specifications

Period length1 mm
Max. Measurement length4,000 mm
System accuracy< ± 10 µm
Repeatability unidirectional< 5 µm
Repeatability bidirectional< 15 µm
Operating speed (absolute)1.5 m/s
Max. Operating speed10 m/s
Working temperature range– 30 … + 85 °C
Protection classIP 65
Operating voltage range7 … 12 V

Frequently asked questions

What is the measurement step at 12-bit interpolation?

The measurement step is 0.244 µm.

What is the maximum permitted ambient field strength for accuracy?

The maximum permitted ambient field strength is < 3 .. 4 kA/m (3.8 .. 5 mT).

How is the sensor adjusted prior to commissioning?

An adjustment run (calibration) is mandatory prior to initial commissioning.