Service manual for the Sharp R-21LTF light-duty commercial microwave oven, covering safety, troubleshooting, tests, repairs, and parts.
This service manual is for the Sharp R-21LTF and R-21LVF light-duty commercial microwave ovens. It is intended for after-sales service and technical repair, with warnings about high-voltage hazards and microwave leakage safety.
The manual includes precautions, product description, operation, troubleshooting, test procedures, touch control panel service, component replacement and adjustment, circuit diagrams, and a parts list.
| Microwave output power | 1000 W |
|---|
Disconnect the power supply cord, remove the outer case, open and block open the door, and discharge the high-voltage capacitor.
It remains charged for about 60 seconds.
The power density should not exceed 1 mW/cm2 before purchase and 5 mW/cm2 thereafter.
Use 275 ±5 ml of tap water initially at 20 ±5°C in a 600 ml beaker.