Shandong Kexin Dianqi CSMS-B100 Series Surge Protector User Manual

User manual for the Shandong Kexin Dianqi CSMS-B100 series surge protector, including specifications, installation, and technical parameters.


Shandong Kexin Dianqi CSMS-B100 Series Surge Protector User Manual - cover page
Brand
山东科信电气
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
524 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
206D7A6D6D23819DB0358C2D7D654E5D

About this manual

The CSMS-B100 series surge protector from Shandong Kexin Dianqi is designed according to GB18802.1 and IEC61643-1 for AC 50 Hz systems at 220 V/380 V and below, including TN-S, TN-C-S, TT, and IT systems. Each module has a nominal discharge current of 60 kA and a maximum discharge current of 100 kA (8/20 μs), and the device is intended for Type II lightning protection at LPZ2 or the LPZ2/LPZ3 boundary.

Features include quality surge components, overcurrent and thermal protection, low leakage current, fast response, low residual voltage, and a pluggable modular design that can be replaced without de-energizing. Installation uses a 35 mm DIN rail; the manual also gives wiring, grounding, fault indication, dimensions, environmental limits, and a 3-year product warranty. This manual is written in Chinese.

What's inside

  • CSMS-B100 Series Surge Protector
  • Product Features and Parameters
  • Installation Instructions
  • Surge Protector Schematic
  • Product Dimensions

Specifications

SPD modelCSMS-B100/AC385-4P
Rated voltage (Un)220 V/380 V
Maximum continuous operating voltage (Uc)385 V/50 Hz
Nominal discharge current (In, 8/20 μs)60 kA
Maximum discharge current (Imax, 8/20 μs)100 kA
Voltage protection level (Up)≤2.4 kV
Response time≤25 ns
Leakage current≤15 μA
Poles1P, 2P, 3P, 4P (optional)
Dimensions (W×H×D)108×90×62 mm
Operating temperature-40 °C to +80 °C
Protection ratingIP20
Installation35 mm standard DIN rail
Product warranty3 years

Frequently asked questions

Which standards does the CSMS-B100 series surge protector follow?

It is designed according to GB18802.1 and IEC61643-1.

What are the nominal and maximum discharge currents?

The nominal discharge current is 60 kA and the maximum discharge current is 100 kA (8/20 μs).

When must the surge protector module be replaced?

Replace it when the module fault indicator window shows red.

What grounding resistance is required?

The grounding resistance should be less than 10 Ω.