Secop BD1.4F-VSD-HD Heavy Duty Direct Current Compressor Datasheet

Secop BD1.4F-VSD-HD heavy duty direct current compressor datasheet with technical specifications, dimensions, and operational error codes.


Secop BD1.4F-VSD-HD Heavy Duty Direct Current Compressor Datasheet - cover page
Brand
SECOP
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
398 KB
Published
15 November, 2026
Updated
15 November, 2026
MD5 checksum
9ACDB12236F03A21F3C1D20844C49F44

About this manual

The Secop BD1.4F-VSD-HD is a heavy duty direct current compressor using R134a refrigerant, designed for 12/24V DC operation with a variable speed brushless DC motor.

This datasheet lists application limits, electrical parameters, dimensions, cooling requirements, performance tables, operational error codes, and accessory part numbers for the compressor and electronic unit.

What's inside

  • Application
  • Motor
  • Design
  • Dimensions
  • Operational errors
  • Accessories for BD1.4F-VSD-HD
  • Wire Dimensions
  • Test conditions

Specifications

RefrigerantR134a
Voltage range9.6 - 17 / 19 - 34 VDC
Displacement0.086 cu.in.
Oil quantity2.64 fl.oz. (polyolester)
Weight (compressor)4.63 lbs
Max condensing temperature140 °F continuous (158 °F short)

Frequently asked questions

What refrigerant does the Secop BD1.4F-VSD-HD compressor use?

It uses R134a refrigerant.

What is the voltage range for the BD1.4F-VSD-HD?

It is 9.6–17 VDC for 12V operation and 19–34 VDC for 24V operation.

What does error code 3 mean on the electronic unit?

It indicates a motor start error, caused by a blocked rotor or high differential pressure.

How much does the compressor weigh?

The compressor weighs 4.63 lbs.

Download PDF (398 KB)