The Scotsman SCN60 is a residential nugget ice machine made up of an ice making system and an insulated ice storage system. The ice making system runs when the ice level becomes low and stops when full; the storage chest has a drain for melting ice and is not refrigerated.

The manual covers installation, operation, and maintenance, including cabinet dimensions, location recommendations, decorating features and door panel attachment, door swing, plumbing for pump and gravity drain models, electrical startup, use, and scale removal. It lists utility requirements such as water pressure, water and air temperature limits, and a 115 volt, 60 Hz, 15 amp circuit.

What's inside

  • Product Description
  • Cabinet Dimensions
  • Location Recommendations
  • Decorating Features
  • Door Panel Attachment
  • Door Swing
  • Plumbing - Pump Model
  • Plumbing: Gravity Drain Model
  • Electrical and Start Up
  • Maintenance

Specifications

Cabinet width14 7/8 in
Cabinet height33 3/8 to 34 3/8 in
Electrical requirement115 V, 60 Hz, 15 A dedicated circuit
Water conductivityat least 10 microSiemens/cm
Minimum water pressure20 psi
Maximum water pressure80 psi
Minimum air temperature50 degrees F
Maximum air temperature100 degrees F
Pump drain heightmaximum 10 feet
Custom door panel weightnot exceeding 15 lb

Frequently asked questions

What electrical circuit does the SCN60 require?

The unit must be on its own 115 volt, 60 Hz, 15 amp circuit.

Can the SCN60 be supplied with reverse osmosis water?

Yes, but the water conductivity must be no less than 10 microSiemens/cm.

Is the door swing reversible?

Yes. The door can be attached to open with hinges on the left or right.

How high can a pump drain model force drain water?

It can force drain water up a maximum of 10 feet.