Installation and commissioning guide for Saunafin EP series sauna control systems, covering copper connector installation, cable length, sensor placement…
This document provides installation instructions for the Saunafin EP series control system intended for sauna heaters. It details the installation of copper connectors, control cable length specifications (standard 15 feet), sensor placement requirements (3" from front/open side, 1" down from ceiling), ventilation setup for indoor and outdoor saunas, and electrical safety warnings regarding wiring and junction box installation. The guide also includes troubleshooting error codes for both Pure 2.0 and Elite control panels. This manual is written in Chinese.
| Standard control cable length | 15 feet |
|---|---|
| Sensor placement distance | 3" to front or open side of heater |
| Sensor placement height | 1" down from ceiling |
| Junction box wiring precaution | Ensure no bare wires make contact with circuit board |
| Error code 1 | Temperature sensor not connected or faulty |
The temperature sensor must be placed 3 inches to the front or open side of the heater, 1 inch down from the ceiling.
The standard control cable length is 15 feet; longer cables are available for order if required.
Position the air inlet and outlet vents as far away from one another as possible, diagonally opposite. The outlet vent should be located high on a wall and be about 19" sq, directed back into the house.