User manual for SALTO's ESDx 2 U x (C) energy-saving device with installation, wiring, and technical specs.
This document provides installation instructions and technical specifications for the SALTO ESDx 2 U x (C) energy-saving device. It details wiring requirements, relay power cut ratings, operating conditions, and safety precautions. The device is designed to work with any SALTO key and features a 30-second activation time. It includes a window detector function and must be installed with a standard electrical box. Wiring must comply with voltage and current ratings, and minimum distances must be maintained between units.
| Input Voltage | 85-265 Vac 50/60 Hz |
|---|---|
| Power Consumption (Idle) | 100mw (110Vac) // 200mw (220Vac) |
| Operating Temperature | 0 ° C to 60 ° C |
| Max Cable Section (Power) | 12 AWG (2.5 mm²) |
The device is factory-configured to activate with a 30-second delay.
The minimum distance between two ESD 8/9xxxx units installed face to face is 80 mm.