The SACOME X-ONE coffee machine service manual provides installation, operation, maintenance, programming, and troubleshooting instructions.
This manual covers all aspects of the SACOME X-ONE coffee machine, including safety cautions, installation requirements, electrical and hydraulic schematics, and optional accessories. Detailed procedures for programming, adjusting coffee temperature, and making various coffee drinks are provided.
Additional sections address alarm messages, counter resetting, troubleshooting guides, and regular maintenance tasks to ensure reliable performance and compliance with environmental directives.
| Heating Power (W) | 3500 |
|---|---|
| Installed Power (W) | 3800 |
| Hot Water Volume (L) | 10 |
| Steam Volume (L) | 3 |
| Weight (kg) – 2G model | 58 |
| Boiler Pressure (MPa) | 1.0 (range 0.8‑1.0) |
The ambient temperature must be between 5 °C and 32 °C and the humidity must not exceed 70 %.
A summary of the procedure for resetting the counters is provided in the manual under the section "SUMMARY OF PROCEDURE FOR RESETTING THE COUNTERS".
The boiler pressure is set to 1 MPa with a permissible range from 0.8 MPa to 1 MPa.