Rockwell Automation GuardMaster MSR57P Speed Monitoring Safety Relay Installation Guide

Installation guide for the GuardMaster MSR57P speed monitoring safety relay, covering wiring, configuration, operation, and safety requirements.


Rockwell Automation GuardMaster MSR57P Speed Monitoring Safety Relay Installation Guide - cover page
Brand
A-B《GuardMaster
Category
Industrial Robot
Document type
Installation Guide
Language
Chinese
Pages
12
File format
PDF
File size
2.6 MB
Published
13 March, 2012
Updated
22 November, 2026
MD5 checksum
266958476937C418B1F672A3798ADAA4

About this manual

This document provides step-by-step instructions for installing the GuardMaster MSR57P speed monitoring safety relay on a DIN rail. It includes wiring diagrams, terminal functions, safety requirements, and technical specifications. The relay is designed for integration into machine safety control systems and requires proper risk assessment before installation. It features multiple safety inputs and outputs, status indicators, and configurable response times. This manual is written in Chinese.

What's inside

  • Installation Steps
  • Wiring Diagram
  • Terminal Functions
  • Safety Requirements
  • Technical Specifications
  • Status Indicators
  • Configuration Locking

Specifications

Safety StandardsIEC/EN60204-1, ISO 12100, IEC 61800-5-2
Safety CategoryCategory 4 and PL e for EN ISO 13849-1; SIL CL1 to CL3 for IEC 61508/EN62061
Power Supply24V dc, 0.8…1.1 x rated voltage
Output Current24V dc, 2 A (outputs 14, 24, 68, 78)
Mounting35 mm DIN rail
Weight350 g (0.77 lb)

Frequently asked questions

What is the power supply voltage for the MSR57P relay?

The power supply voltage is 24V dc, with a tolerance of 0.8 to 1.1 times the rated voltage.

What safety standards does the MSR57P relay comply with?

It complies with IEC/EN60204-1, ISO 12100, and IEC 61800-5-2.

How do I install the MSR57P relay on a DIN rail?

Mount the relay by hanging the top slot onto the DIN rail, pressing down until you hear a click, and securing it with end plates on both ends.

What is the maximum current draw of the MSR57P relay?

The maximum current draw is 10.4A (terminal A1 + 13).