RME LNI-2 DC Super Low Noise DC Power Filter & Stabilizer User's Guide

The RME LNI-2 DC User's Guide describes this super low noise DC power filter and stabilizer with 12 volt, 2 amp output for connected audio devices.


RME LNI-2 DC Super Low Noise DC Power Filter & Stabilizer User's Guide - cover page
Brand
rme
Category
Power Management
Document type
User Manual
Language
English
Pages
18
File format
PDF
File size
558 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
189A0B130EDDC25353B76D9AD628D5FC

About this manual

The RME LNI-2 DC is a super low noise DC power filter and stabilizer for connected 12 volt audio devices. It accepts a universal 9 to 18 volt DC input and provides 12 volt, 2 amp, 24 watt DC output with galvanic isolation between input and output, integrated HF/RF filtering, and a muFilter output. The guide also describes overload, short circuit, and overheating protection, a two-color status LED, and a ground terminal.

The manual covers package contents, proper use, connectors and LED operation, and installation and first-time operation with the enclosed DC sensor cables. It also includes ground terminal use, troubleshooting, and technical specifications and background, including noise measurements and a block diagram.

What's inside

  • Introduction
  • Package Contents
  • Proper Use
  • Brief Description and Characteristics
  • Connectors – LED
  • Installation and First Time Operation
  • Using the Ground Terminal
  • Hotline – Troubleshooting
  • Technical Specifications
  • Technical Background

Specifications

Input voltage range9 – 18 V DC
Output voltage12.0 V
Continuous output current2.0 A
Continuous output power24 Watt
Noise< 2 µV
Dimensions80 x 30 x 123 mm
Weight605 g (1.33 lbs)

Frequently asked questions

What DC input voltage does the RME LNI-2 DC accept?

It accepts a 9 to 18 volt DC input, center pin positive. The input connector is 2.1x5.5mm, lockable or normal.

What is the DC output of the RME LNI-2 DC?

The output is 12.0 volts at a continuous 2.0 amps, for 24 watts. Maximum output current is 3.0 amps.

How do I connect the RME LNI-2 DC for first use?

Plug the enclosed DC power cable into the muFilter output, connect the other side to the device to be powered, and plug a suitable DC power source into the LNI-2 DC input jack. Both top LEDs should turn on in white, and the connected device can then be switched on.

What do the LEDs on the RME LNI-2 DC indicate?

The LED near the rear output jack signals normal operation in white or failure in red. The LED near the input jack confirms input voltage.