Installation guide for Regal Rexnord EM Replacement Control Module Kit compatible with Genteq® X13, Endura® Pro and Evergreen EM motors.
This guide provides step-by-step instructions for replacing control modules in compatible motors. It includes safety warnings, installation procedures, diagnostic tests, and troubleshooting for rotation issues. The kit includes the control module, mounting bolts, and optional low voltage harness. Proper voltage and horsepower matching are required for safe installation.
The guide also covers motor diagnostics, rotation sensing, and how to reverse motor direction if needed. Safety precautions include disconnecting power before installation and using qualified technicians. The document is updated as of June 2022 and includes contact information for customer support. This manual is written in Chinese.
| Allowable Voltage Range | 115 VAC models (90-132 VAC), 208-230 VAC models (180-264 VAC) |
|---|---|
| RPM | 1075 |
| Speeds | 5 (24 VAC inputs) 3 (24 VDC inputs) PWM (600-1200 RPM range) |
| Rotation | Dual - Auto Rotation Sensing |
| Ambient Rating | 1/3 & 1/2 HP models (-20 to 65°C), 3/4 & 1 HP models (-20 to 45°C) |
It can replace ECM control modules in Genteq® X13, Endura® Pro, and Evergreen EM motors.
Match the horsepower (HP) and voltage (VAC) ratings of the new control to the one being replaced. RPM and amperage do not need to match.
Disconnect all 24 VAC speed taps, connect terminals 1, 3, and 5 to a 24 VAC power source, power on, wait 5 minutes, then reconnect the speed taps and power on again.