Radicon ILU-1.00GB1211 Gear Units Approved Lubrication Manual

Radicon approved lubrication manual (ILU-1.00GB1211) listing approved lubricant grades, oil suppliers and minimum operating temperatures for Radicon gear units.


Radicon ILU-1.00GB1211 Gear Units Approved Lubrication Manual - cover page
Brand
Radicon
Category
Other products
Document type
User Manual
Language
English
Pages
16
File format
PDF
File size
440 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
5FFCA4B8BC02056AC7A2A1C49D493186

About this manual

This approved lubrication manual, document reference ILU-1.00GB1211, covers lubricant selection for Radicon industrial gear units. Radicon manufactures a range of helical, worm and bevel helical gear units and geared motors (Series A, B, C, F, G, H, J, K and M), screwjack wormgear units, gear pumps and couplings, serving mechanical drive applications in industries including food, energy, mining, metal, automotive, aerospace and marine propulsion.

The manual lists approved lubricants in tables organised by Radicon grade numbers (0M–9M, 0A–9A, 0E–9E), giving corresponding oil supplier designations and the recommended minimum operating temperature in °C for each product. Specification notes explain oil change periods, restrictions on certain lubricant types, and rules such as not mixing different oil types and consulting Radicon engineers when in doubt.

What's inside

  • Products in the range
  • Specification notes
  • Table M – Straight mineral oils
  • Table A – Mineral oils with mild EP or anti-wear additives
  • Table E – Mineral oils with industrial EP additives
  • Lubricant selection
  • Oil change period
  • Minimum operating temperatures

Specifications

Recommended lubricant gradeGiven on the gear unit nameplate
Type E lubricant temperature limitNot above 70°C in units containing copper alloys
Elevated temperature limitConsult oil supplier above 80°C

Frequently asked questions

Can different types or brands of oil be mixed in a Radicon gear unit?

No. Different types or brand names of oils must not be mixed; if changing the oil type, the gear unit must be thoroughly flushed.

Where do I find the recommended lubricant grade for my gear unit?

All Radicon gear units have a nameplate that should give the recommended lubricant grade number; if not, guidance is in the appropriate Gear Catalogue and/or Installation and Maintenance Manual.

What do the numbers in brackets in the lubricant tables mean?

They indicate the recommended minimum operating temperature in °C. The unit must not run below this temperature.

Can synthetic lubricants be used instead of mineral oils?

Synthetic lubricants of types G and H can be used in most applications as an alternative to mineral-based products, but Radicon engineers should be consulted before using them.