Prokit MT-4618 Sound Level Meter User's Manual

Prokit MT-4618 sound level meter user's manual: battery setup, A/C weighting, FAST/SLOW response, MAX hold, 30-130 dB range and specifications.


Prokit MT-4618 Sound Level Meter User's Manual - cover page
Brand
Prokit
Category
Analyzer
Document type
User Manual
Language
English
Pages
16
File format
PDF
File size
1 MB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1142554ECDC5E108E805A448C5773876

About this manual

The Prokit MT-4618 is a digital sound level meter used to measure the ambient sound level around factories, workshops, schools, residential areas, offices, roads and audio equipment, and for noise engineering, product quality control and health prevention. It complies with IEC651 Type 2 and ANSI S1.4 Type 2, covers a measuring scope of 30 to 130 dB with automatic shifting, and provides A and C weighting networks, FAST/SLOW response rates, a MAX locking function and a backlight.

This first edition (2020) user's manual gives the safety instructions and operating environment, explains the LCD display symbols, lists the functional characteristics and specifications, and then describes preparations before use and the basic usage methods: installing four AAA batteries, selecting a measurement gear level when UNDER or OVER appears, choosing the A or C weighting mode and FAST or SLOW response, using the MAX key and lighting the backlight. Closing notes cover use around hot or humid conditions, battery removal and the anti-wind ball. The document contains English text followed by a traditional Chinese section.

What's inside

  • Safety instructions
  • LCD display introduction
  • Functional characteristics description
  • Specifications
  • Preparations before use
  • Basic usage methods
  • Notes

Specifications

ComplianceIEC651 Type 2 and ANSI S1.4 Type 2
Measuring range30 to 130 dBA, 30 to 130 dBC
Sound pressure accuracy±1.5 dB at 94 dB @ 1 kHz; ±5 dB at 94 dB @ 8 kHz
Frequency response30 Hz - 8 kHz
Dynamic range50 dB for each measurement gear level
Measurement gear levels30-80, 40-90, 50-100, 60-110, 70-120, 80-130 dB (6 levels)
Frequency weightingA and C weighting networks
Dynamic characteristicFAST 125 ms, SLOW 1 sec
MicrophonePolarized capacitive microphone
Digital display4-digit, resolution 0.1 dB, sampling rate 2 times/sec
Power supplyAAA x 4 batteries of 1.5 V each
Operating temperature0 to +40 °C
Storage temperature-10 to +60 °C
Dimensions193 (L) x 60 (W) x 29 (H) mm
AccessoriesInstruction manual, cotton ball

Frequently asked questions

What is the measuring range of the MT-4618 sound level meter?

It measures from 30 to 130 dB, with automatic shifting that selects the best gear level within that range.

Which batteries does the meter use?

Four AAA 1.5 V alkaline batteries, installed in the battery holder after opening the back cover with a Phillips head screwdriver.

What do the UNDER and OVER symbols mean?

UNDER means the gear level of the instrument is too high, and OVER means it is too low, so the reading is not accurate until the level is adjusted.

Which weighting mode should I use to measure sound as the human ear hears it?

Select the A weighting mode, which simulates the hearing characteristics of human ears; select C weighting to measure the actual sound level.

What standards does the meter comply with?

The manual states it complies with IEC651 Type 2 and ANSI S1.4 Type 2.