Operating instructions for Pfeiffer Vacuum's BG 5138 BEN / A ceramic capacitance gauge, covering safety, installation, operation, and technical data.
This manual provides operating instructions for the BG 5138 BEN / A ceramic capacitance gauge, part of the CMR 37X series. It covers safety precautions, installation procedures, operational steps including zeroing and factory reset, technical specifications, and maintenance guidelines. The gauge measures absolute pressure of gases with high accuracy using a temperature-compensated ceramic diaphragm. It is designed for use in industrial vacuum applications and requires proper power and vacuum connections as specified.
| Measurement Range | 1 V to 9.8 V |
|---|---|
| Accuracy | 0.15% of reading |
| Output Signal | Analog (measuring signal) |
| Voltage Range | 0 … +11 V |
| Output Impedance | 0 Ω (short-circuit proof) |
| Response Time | 30 ms to 130 ms |
| Supply Voltage | +14 … +30 VDC |
| Power Consumption | ≤12 W (heated), ≤8 W (operating) |
| Degree of Protection | IP 40 |
The measurement range is from 1 V to 9.8 V.
The accuracy is 0.15% of reading.
The gauge provides an analog measuring signal.
The supply voltage range is +14 … +30 VDC.