The manual provides safety instructions, installation, operation, maintenance and spare‑parts information for the Pesce AC10SN/A centrifugal feeder.
This operation and ordinary maintenance manual covers all aspects of the AC10SN/A centrifugal feeder, including general information, safety devices, installation steps, start‑up procedures, regular operation, and troubleshooting. It also lists the spare parts and provides guidance for dismantling and waste disposal.
The document is organized into sections such as General Information, Characteristics, Safety Instructions, Installation, Start‑up, Using the Machine, Regulations, Maintenance, Dismantling, and Spare Parts, making it easy for operators and service technicians to find the required information. This manual is written in Italian.
| Installed electric power | 0.27 kW |
|---|---|
| Absorbed electric power | 0.17 kW |
| Electric motor power | 0.246 kW |
| Air pressure of utilisation | 0.5 MPa |
| Operative temperature | 5 – 40 °C |
| Operating humidity (no condensate) | 30 – 80 % |
| Machine weight | ≈ 290 kg |
Chapter 3 – SAFETY MECHANISMS contains important safety information and warnings.
The machine identification data is on the CE rating plate placed on the external structure over the exit head.
The feeder requires an air pressure of 0.5 MPa for normal operation.