Perkins 4000 Series 4008TAG1A/2A ElectropaK Diesel Engine Data Sheet

Data sheet for the Perkins 4000 Series 4008TAG1A/2A ElectropaK diesel engine, covering ratings, specifications, dimensions and fuel consumption.


Perkins 4000 Series 4008TAG1A/2A ElectropaK Diesel Engine Data Sheet - cover page
Brand
Perkins
Category
Generator
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
108 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
2A04B69D78233BC971077E1D8AAA7886

About this manual

The Perkins 4000 Series family includes 6, 8, 12 and 16 cylinder diesel engines. The 4008TAG1A/2A ElectropaK units are turbocharged, air-to-air charge-cooled, 8-cylinder in-line diesel engines offered with Temperate or Tropical cooling packages, with or without fuel cooling.

The data sheet lists typical generator engine power ratings at 1500 rev/min, rating definitions for baseload, prime and standby power, general engine data, dimensions and dry weights, optional equipment and fuel consumption for both models. Ratings are stated at 25°C air inlet temperature, 100 kPa barometric pressure and 30% relative humidity.

What's inside

  • Economic power
  • Reliable power
  • Clean, efficient power
  • Operation Type
  • Rating definitions
  • Standard ElectropaK Specification
  • General Data
  • Optional Equipment
  • Fuel Consumption

Specifications

Number of cylinders8 vertical in-line
Bore and stroke160 mm x 190 mm
Displacement30.561 litres
AspirationTurbocharged and air-to-air charge cooled
Combustion systemDirect injection
Compression ratio13.6:1
Cooling systemWater-cooled
Total lubrication system capacity153 litres
Length3852 mm (Temperate), 3711 mm (Tropical)
Dry weight4270 kg* (Temperate), 4320 kg* (Tropical)

Frequently asked questions

What cooling packages are offered for the 4008TAG1A/2A?

Temperate or Tropical cooling packages are offered, with or without fuel cooling.

What is the displacement of the 4008TAG1A/2A engine?

The displacement is 30.561 litres.

What fuel specification is listed?

The listed fuel specification is BS2869 Class A1+A2 or ASTM D975 No 2D.

What are the reference rating conditions?

The reference conditions are 25°C air inlet temperature, 100 kPa barometric pressure and 30% relative humidity.