Panasonic NE1257R/NE1258R/NE1757R/NE2157R/NE2180/NE3280 Commercial Microwave Oven Magnetron Test Bulletin

Technical bulletin for testing magnetrons in Panasonic commercial microwave ovens for opens, shorts, or insufficient power.


Panasonic NE1257R/NE1258R/NE1757R/NE2157R/NE2180/NE3280 Commercial Microwave Oven Magnetron Test Bulletin - cover page
Brand
Panasonic
Category
Microwave oven
Document type
Service Manual
Language
English
Pages
2
File format
PDF
File size
72 KB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
1B87013333BDF85CC997DFD6ECD24A71

About this manual

Panasonic technical bulletin E10-2010-06 covers magnetron testing for the NE1257R, NE1258R, NE1757R, NE2157R, NE2180, and NE3280 commercial microwave ovens. It describes checks for open or shorted magnetrons and a temperature test for weak magnetrons.

The bulletin includes ohm-meter resistance checks of the filament and magnetron casing, a water-temperature rise test with per-magnetron values, and field expedient power determination benchmark times by model.

What's inside

  • Magnetron open or shorted test
  • Temperature test for weak magnetron
  • Step 1: filament resistance check
  • Step 2: casing resistance check
  • Field expedient power determination tests

Specifications

Filament resistanceLess than 1 Ω
Magnetron-to-casing resistanceInfinity (open circuit)
Water volume for temperature test8 oz (1 cup)
Starting water temperatureApproximately 70°F
Expected temperature riseApproximately 142°F
Temperature rise per magnetron (2-magnetron ovens)Approximately 70°F
Temperature rise per magnetron (4-magnetron ovens)Approximately 35°F
Field expedient power test time (NE-1257/8)2:15
Field expedient power test time (NE-1757)1:35
Field expedient power test time (NE-2157)0:54
Field expedient power test time (NE-2180)0:54
Field expedient power test time (NE-3280)0:40

Frequently asked questions

How do I test a magnetron for opens or shorts?

Unplug the unit, discharge all H.V. capacitors, and disconnect all leads from the magnetron terminals. Then use an ohm meter: less than 1 Ω between terminals indicates a good filament, and infinity from a terminal to the casing indicates no short.

How can I tell if a magnetron is weak?

Heat exactly 8 oz of water and check the temperature rise; it should rise about 142°F. If lower, test magnetrons individually: about 70°F per magnetron in two-magnetron ovens or 35°F in four-magnetron ovens.

What are the field expedient power test benchmark times?

For 1 cup of water in a Pyrex measure, benchmark times are 2:15 for NE-1257/8, 1:35 for NE-1757, 0:54 for NE-2157 and NE-2180, and 0:40 for NE-3280.

What should I do before testing the magnetron?

Unplug the unit, discharge all H.V. capacitors, and disconnect all leads from the magnetron terminals.