Service manual for Panasonic CS-LZ25TKE and CS-LZ35TKE air conditioners covering R32 refrigerant safety, specifications, installation, troubleshooting and…
This service manual covers the Panasonic CS-LZ25TKE and CS-LZ35TKE indoor units and the CU-LZ25TKE and CU-LZ35TKE outdoor units for North Europe. It is intended for experienced repair technicians and includes safety precautions, R32 refrigerant guidance, specifications, features, dimensions, wiring and circuit diagrams, installation instructions, operation control, protection control, troubleshooting, disassembly, service data, exploded views and replacement parts lists.
The document states that the air conditioner contains and operates with R32 refrigerant and must only be installed or serviced by qualified personnel. It also includes warnings about flammable refrigerant, copper pipe thickness, residual oil, and the need to follow local legislation and installation manuals before maintenance or service.
| Indoor unit model | CS-LZ25TKE, CS-LZ35TKE |
|---|---|
| Outdoor unit model | CU-LZ25TKE, CU-LZ35TKE |
| Destination | North Europe |
| Refrigerant | R32 |
| Copper pipe thickness | More than 0.8 mm |
| Residual oil | Less than 40 mg/10 m |
The air conditioner contains and operates with R32 refrigerant.
Only qualified personnel must install or service the product.
Copper pipes used with R32 must be more than 0.8 mm thick.
These models are intended for North Europe.