Installation manual for OSO unvented hot water cylinders covering siting, pipework, commissioning, safety and maintenance.
This manual provides installation details for OSO unvented hot water cylinders. It covers component identification, cold water supply and hot water outlet connections, filling, draining, commissioning, safety cut-out operation, and maintenance of the Multibloc control valve.
It also includes dimension and weight information, tundish and discharge pipe requirements, and notes on compliance with legislation and codes of practice.
| Supply pressure | Up to 16 bar |
|---|---|
| Pressure reducing valve setting | 2.1 bar |
| Expansion relief valve setting | 8.0 bar |
| Tundish maximum distance from relief valve drain | 500 mm |
| Tundish pipework minimum vertical length | 300 mm |
| Maximum length of 22 mm discharge pipework | 9 m |
| Bend equivalent length | 0.8 m per bend or elbow |
| Cold water supply pipe size | 22 mm nominal |
| Tundish pipework size | 22 mm |
It is designed for supply pressures up to 16 bar; for pressures over 16 bar, an additional pressure reducing valve must be fitted.
The tundish must be installed within a maximum of 500 mm from that connection.
Turn off the electrical supply to the immersion heater, isolate an indirect unit from the boiler, and contact the installer or competent engineer.
Under normal circumstances it should not require maintenance, but annual inspection and/or cleaning may be necessary depending on local water conditions.