Installation and maintenance guide for Oras Electra 6100, 6200, 6130 and 6230 touchless faucets, with technical data and installation steps.
The Oras Electra 6100, 6200, 6130 and 6230 are touchless faucets. This document gives technical data, installation instructions, cleaning guidance, frost protection information and safety shut-off information for the models.
The guide lists protection classes, sensor range, afterflow period, maximum flow period, electrical connections and spare parts. It also describes how the faucet opens and closes through a solenoid valve controlled by a photocell. This manual is written in German.
| Protection class, 6100/6200 | IP 67 |
|---|---|
| Protection class, 6130/6230 | IP 67 / transformer IP 40 |
| Afterflow period | 1 s (0 - 255 s) |
| Maximum flow period | 2 min (1 - 255 s) |
| Electrical connection, 6100/6200 | 230 VAC |
| Electrical connection, 6130/6230 | 230/12 VAC |
| Operating pressure | 50 - 1000 kPa |
| Flow rate | 0.11 l/s (300 kPa) with flow controller |
| Maximum water temperature | max. +80°C |
It opens and closes through a solenoid valve controlled by a photocell.
The faucet closes automatically.
Use only neutral cleaning agents and not acid- or sand-containing products.