OPTIBELT V-Grooved Pulleys with Taper Bushes Installation and Maintenance Manual

Installation and maintenance instructions for OPTIBELT V-grooved pulleys with taper bushes, covering alignment, tightening torques, belt tension, and…


OPTIBELT V-Grooved Pulleys with Taper Bushes Installation and Maintenance Manual - cover page
Brand
Optibelt
Category
Industrial Robot
Document type
Service Manual
Language
English
Pages
24
File format
PDF
File size
2.9 MB
Published
24 October, 2026
Updated
24 October, 2026
MD5 checksum
E70FD2396FF65577277C43028DAD997C

About this manual

This manual provides installation and maintenance instructions for OPTIBELT V-grooved pulleys equipped with taper bushes. It details procedures for vertical and horizontal alignment, screw tightening torques for various models, and belt tensioning methods. Safety precautions and inspection recommendations are also included to ensure proper operation and longevity of the drive system.

What's inside

  • Safety Instructions
  • Vertical Alignment
  • Horizontal Alignment
  • Tightening Torques
  • Belt Tension
  • Inspections
  • Installation Steps
  • Disassembly
  • Tension Testers
  • Troubleshooting

Specifications

Maximum shaft deviation0.5°
Recommended inspection interval3 to 6 months
Belt tension check timing0.5 to 4 hours
Tightening torque for TB 10085.7 Nm
Tightening torque for TB 5050275.0 Nm

Frequently asked questions

When should belt tension be checked after installation?

Belt tension should be checked again after 0.5 to 4 hours and corrected if necessary.

How often should the drive be inspected?

The drive should be inspected regularly, for example after 3 to 6 months.

What is the maximum permissible shaft deviation?

The maximum permissible shaft deviation is 0.5°.