User and maintenance guide for Nuvair EK100 rotary screw compressor with safety, operation, and lubrication instructions.
This manual provides safety warnings, operational procedures, and maintenance instructions for the Nuvair EK100 rotary screw compressor. It covers safety precautions, compressor cycle mechanics, lubrication systems, and electrical controls. Users must read and understand all instructions before operating the equipment to prevent injury or damage. The manual includes diagrams and component descriptions for proper maintenance and troubleshooting.
| Maximum Pressure | 217 psig |
|---|---|
| Minimum Discharge Pressure | 65 psig |
Compression is achieved by meshing helical rotors: the main rotor has five lobes and the secondary rotor has six grooves. Air is drawn in, compressed, and discharged in a continuous cycle.
Do not exceed the rated maximum pressure values shown on the nameplate.
This device maintains minimum pressure (65 psig) within the air/oil sump.
A Wye/Delta reduced voltage starter provides control and overload protection.