Service manual for Norcold N6XX/N8XX refrigerators covering the no co fault code and power board reset procedures.
Norcold N6XX/N8XX Series Refrigerator Service Manual describes troubleshooting for a no co fault code, meaning no cooling detected by the controls. It includes checks for ventilation obstructions, leveled operation, cooling at the fin assembly, and cooling unit replacement when the code appears before a full cooling cycle.
The manual also gives power board reset procedures. Earlier controls are reset by jumpering Pin 15 to ground, while later units use an optical display reset or Procedure 2 or Procedure 3 depending on model and serial number.
It indicates no cooling detected by the controls.
Jumper Pin 15 on the 16-pin connector to the power board ground lug for 10-15 seconds.
A six inch long insulated 22 AWG wire with 1/2 inch of insulation stripped from each end.
Replace it if the "no co" code shows before completing a full cooling cycle.