Nikon Ti2 Eclipse Microscope User Manual

Nikon Ti2 Eclipse microscope user manual covering startup, software, cameras, objectives, imaging acquisition, autofocus, data saving, and TIRF alignment.


Nikon Ti2 Eclipse Microscope User Manual - cover page
Brand
Nikon
Category
microscope
Document type
User Manual
Language
English
Pages
29
File format
PDF
File size
2.5 MB
Published
24 November, 2026
Updated
24 November, 2026
MD5 checksum
0431D2A2CCF345B88EA5181FED740BD1

About this manual

This Nikon Ti2 Eclipse user manual describes how to turn the system on and off, start NIS -ELEMENTS, select a camera, view through the microscope, and set up live cell imaging. It also lists the available objectives and their NA, working distance, contrast method, and application.

The guide covers phase contrast acquisition, Köhler adjustment, automated ND acquisitions, multichannel and fluorescence filter setup, large image and timelapse acquisition, PFS autofocus, multipoint and Z-acquisition, scale bars, data saving, and TIRF alignment.

What's inside

  • How to turn on the system
  • How to turn off the system
  • Starting the software
  • Viewing through the microscope
  • Which camera should I use?
  • Live cell imaging setup
  • Objectives available on the system
  • Phase contrast acquisition
  • Köhler adjustment and phase contrast
  • TIRF alignment

Specifications

TIS camera resolution2048 x 2048 pixels
Fi3 camera resolution2880 x 2048 pixels
10x phase contrast objectiveAir Plan Fluor; NA 0,30; WD 15,2 mm; Ph 1 / phase contrast
20x phase contrast objectiveAir Plan Fluor (coverslip correction); NA 0,45; WD 7,4 mm; Ph 1 / phase contrast
20x fluorescence objectiveAir Plan Apochromat lambda; NA 1,20; WD 1,0 mm; fluorescence
40x fluorescence objectiveAir Plan Apochromat lambda (coverslip correction); NA 0,95; WD 0,21 mm; fluorescence
60x TIRF / fluorescence objectiveOil CFI Apo TIRF (coverslip and temperature correction); NA 1,49; WD 0,12 mm; TIRF / fluorescence
100x fluorescence objectiveOil CFI Plan Apochromat lambda; NA 1,45; WD 0,13 mm; fluorescence

Frequently asked questions

Which camera should I use for fluorescent samples?

Use the TIS camera for imaging of fluorescent samples.

Which camera should I use for brightfield, phase contrast and histological samples?

Use the Fi3 camera for brightfield, phase contrast and histological samples.

Which objectives require immersion oil?

The 60x and 100x objectives must be used with immersion oil; the other objectives are dry.

Do I need a password for the user account in NIS -ELEMENTS?

No password is needed for the user account.

Download PDF (2.5 MB)

More Nikon Manuals


View all Nikon manuals →