Neo-Dyn Enclosure 3X Pressure Switches Installation and Operation Manual

This manual covers installation, adjustments, and specifications for Neo-Dyn Enclosure 3X pressure switches, including models 130P through 232P.


Neo-Dyn Enclosure 3X Pressure Switches Installation and Operation Manual - cover page
Brand
Neo-Dyn
Category
Other Electronics
Document type
User Manual
Language
English
Pages
21
File format
PDF
File size
83 KB
Published
06 November, 2026
Updated
06 November, 2026
MD5 checksum
C40F4C9581BF95896A96EE5779308E18

About this manual

This document serves as the installation and operation manual for Neo-Dyn Enclosure 3X pressure switches, covering models 130P, 131P, 132P, 181P, 231P, 232P, 125P, and 225P. These weatherproof electromechanical devices are designed for pneumatic and hydraulic systems up to 10,000 psig. The manual provides instructions for mounting, process connections, electrical wiring, and setpoint adjustments for both adjustable and factory-set units.

What's inside

  • Introduction
  • Customer Service
  • Mounting
  • Process Connection
  • Electrical Connections
  • Setpoint Adjustment
  • Troubleshooting
  • Specifications
  • Options
  • Warranty Information

Specifications

Maximum Operating Pressure10,000 psig
Standard Pressure Port (130P)¼” - 18 NPT male
Standard Pressure Port (131P, 181P, 231P)½” - 14 NPT Male and ¼” - 18 NPT Female
Standard Pressure Port (125P, 132P, 225P, 232P)¼” - 18 NPT Female
Weight20 ounces (0.6 kg)
Electrical Rating (Form C3X)11 amp at 125 or 250 VAC
Electrical Rating (Form CC3X)11 amp at 125 or 250 VAC
Ingress ProtectionIP66

Frequently asked questions

What is the maximum operating pressure for these switches?

The switches are designed for applications in pneumatic and hydraulic systems up to 10,000 psig.

What are the standard wetted materials?

The most common wetted materials include a polyimide (Kapton) sensing diaphragm, nitrile O-ring, and aluminum alloy or corrosion resistant steel pressure port.