TP4056 is a complete single-cell lithium-ion battery linear charger using constant-current/constant-voltage operation. It is offered in an 8-pin ESOP/EMSOP package with a heat-sink pad on the bottom, and it can operate from a USB supply or an adapter supply. The charge voltage is fixed at 4.2 V, and the charge current is set by an external resistor. Internal PMOSFET architecture and reverse-charge protection eliminate the need for an external isolation diode.

Thermal feedback automatically adjusts the charge current to limit chip temperature under high-power or high-ambient-temperature conditions. Charging terminates automatically when the current falls to 1/10 of the set value, and the device automatically starts a new cycle when the battery voltage falls below the recharge threshold. Status outputs indicate charging and charge completion. Applications listed in the datasheet include mobile phones, PDAs, MP3/MP4 players, digital cameras, electronic dictionaries, GPS and portable equipment. This manual is written in Chinese.

What's inside

  • Applications
  • Description
  • Features
  • Absolute Maximum Ratings
  • Package/Ordering Information
  • Electrical Characteristics
  • Typical Performance Characteristics
  • Pin Functions
  • Block Diagram
  • Principle of Operation

Specifications

Programmable charge currentUp to 1000 mA
Preset charge voltage4.2 V, ±1% accuracy
Standby supply current55 µA
Battery leakage current in low-current stateLess than 2 µA
Trickle charge voltage2.9 V
Package8-pin ESOP/EMSOP with heat-sink pad
Operating ambient temperature range-40°C to 85°C
Maximum junction temperature145°C
BAT pin current (absolute maximum)1200 mA

Frequently asked questions

What is the preset charge voltage of the TP4056?

It has a 4.2 V preset charge voltage with ±1% accuracy.

How is the charging current programmed?

An external resistor connected from PROG to ground sets the charging current.

When does the TP4056 terminate a charge cycle?

It terminates automatically when the charge current falls to 1/10 of the set value after reaching the final float voltage.

What happens when the input supply is removed?

The TP4056 enters a low-current state and reduces battery leakage current to below 2 µA.