Mosaic Industries 1DC Relay Wildcard Users Guide

User guide for the Mosaic Industries 1DC Relay Wildcard solid‑state DC relay module.


Mosaic Industries 1DC Relay Wildcard Users Guide - cover page
Brand
Mosaic Industries
Category
Other Electronics
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
165 KB
Published
03 October, 2026
Updated
03 October, 2026
MD5 checksum
644353BF05957A1A2DAA09D41920E4D3

About this manual

This guide explains the hardware and software of the Mosaic Industries 1DC Relay Wildcard solid‑state DC relay module. It covers the module’s specifications, wiring, address configuration, and the C/FORTH code needed to initialize and control the relays.

The document also provides detailed connection instructions for the Module Carrier Board, explains how to set module addresses with jumper shunts, and includes example software routines for initializing, turning relays on/off, and reading relay status.

What's inside

  • Introduction
  • DC Relay Wildcard Specifications
  • Hardware Overview
  • Connecting to the Module Carrier Board
  • Selecting the Module Address
  • Software
  • Initializing the Module
  • Controlling a Relay
  • Conclusion

Specifications

ChannelsThree independent, optically isolated solid state DC relays
Voltage Controls3 - 60 VDC
Current Switchesup to 3 A continuously, 12 A surge for 10 ms
IsolationOptically isolated to 2500 V rms
Maximum ON Voltage Drop0.4 VDC
Maximum OFF Leakage Current100 µA
Turn‑On Time50 µsec
Turn‑Off Time300 µsec
Control Voltage Range3.0‑9.0 VDC
Nominal Input Impedance270 Ω

Frequently asked questions

How many DC loads can the module control?

The module can control up to three 3 A DC loads.

How many modules can be stacked on the carrier board?

Up to eight DC Relay Modules can be stacked on the Module Carrier Board.

What is the maximum surge current the relays can handle?

Each relay can handle a surge of 12 A for 10 ms.